Business
Heavy Duty Fan
Features
We provide high-efficiency, high-wear resistance, and high-corrosion resistance fans.
  • Maximized energy saving through high efficiency fan

    ·Through continuous research and development, we provide high-efficiency fan that achieves over 85% energy efficiency, ensuring superior performance and significant energy savings for your operations.

    ·We offer expert solutions to maximize energy savings by conducting performance diagnostics on existing fan, optimizing their efficiency and ensuring long-term operational benefits.

  • Extend equipment life and reduce costs with high-durability solutions

    ·Special impeller coatings that significantly improve wear and corrosion resistance, ensuring long-lasting durability and reliable performance in demanding environments.

    ·Deliver significant cost savings by offering more than double the extended lifespan and energy efficiency exceeding 80% even in the harsh environment.

  • Providing all-in-one package

    ·We offer a complete, all-in-one package of fan parts and components, including bearing housings, couplings, dampers, control actuators, and joints, ensuring seamless and uninterrupted support for your equipment needs.

  • Advanced product technology for specialized environments

    ·Our special titanium impeller coating provides outstanding wear and corrosion resistance, making it ideal for environmental pollution prevention applications, including exhaust gas desulfurization facilities.

    ·We provide high temperature fan that can be used up to 500℃.

  • 24/7 Professional maintenance support

    ·We provide 24/7 professional maintenance support and ensure your equipment maintains optimal operating conditions in any environment.

Applications

Harsh industrial environments and general industrial environments such as cement, iron and steel manufacturing, and power generation

Pneumatic conveying of raw materials

Hot gas/vapour exhaust and ventilation

Dust and solid particle capture and dust collection

Process cooling

Model and Specifications

Centrifugal Fan

MODEL Induced Draft Fan/Blower Forced Draft Fan/Blower Circulation & Cooling Fan Dust Collector Fan Ventilation Fan
Max. Flow (㎥/min) 16,200 3,000 1,100 4,500 1,100
Max. Pressure (㎜Aq) 2,800 2,000 600 500 100
Max. Temperature 500℃ 500℃ 500℃ 40℃ ~ 70℃ 100℃
Fluid Air(Chemicals, Dust, Solid Particles, Liquid Droplets) Air(Chemicals, Dust, Solid Particles, Liquid Droplets) Air Air Air
Diameter 800 ~ 3,500㎜ 500 ~ 1,800㎜ 310 ~ 1,500㎜ 800 ~ 2,000㎜ 100 ~ 800㎜

Axial Fan

MODEL Axial Fan Jet Fan Ventilation Fan
Max. Flow (㎥/min) 5,000 1,000 800
Max. Pressure (㎜Aq) 100 100 100
Max. Temperature -20℃ ~ +300℃ -20℃ ~ +300℃ 40℃ ~ 70℃
Fluid Air and Fumes Air, Fumes, and Smokes Air and Fumes
Diameter 600 ~ 2,500㎜ 300 ~ 1,200㎜ 300 ~ 800㎜